Rethinking the Security of Air Valves

April 2, 2018

About the author: John V. Ballun is a contributing author. For additional information, contact Val-Matic Valve & Mfg. Corp. at 630/941-7600 or by e-mail at [email protected].

undefined

Prior to cross connection and security issues, valve vaults were simply a part of the water distribution system that received little or no attention unless a problem occurred. With the advent of cross connection issues, an increasing number of municipalities became concerned with the potential for non-potable water entering a pipeline through vault-installed air valves. Often, the valve outlets were not piped, leaving them exposed to floodwater or other contaminates.

As a result, municipalities began to insist that all air valve outlets be piped above grade using a J pipe configuration; however, this proved to be impractical if not impossible in vaults below streets, etc., and also opened up the possibility of malicious tampering with the J pipe. Additionally, in cold climates the air valve outlet would be exposed to frigid temperatures, leading to freezing concerns.

Air valve concerns

Post September 11, 2001, water distribution systems were recognized as one of the nation’s most vulnerable infrastructure assets. Once again, air valve outlets were recognized as having the potential to allow the entry of contamination into a potable water system.

Air valves play an important role in the operation of distribution systems: Air release valves provide efficiency by preventing air pockets from developing at system highpoints, reducing capacity and increasing pressure loss; air/vacuum valves allow the system to discharge large volumes of air upon system start-up and admit air when necessary to prevent a vacuum from forming and creating a pressure surge. Reservoir vents also play an important role in the intake and exhaust of air from reservoirs as the water level inside rises and falls.

Efforts to make J pipe configurations more secure have been underway for some time now. Screens mounted at the end of the pipe, as well as in the pipe itself, are now in use. But J pipes still do not solve the problem of floodwater or intentional introduction of a contaminate that finds its way to an air valve outlet or reservoir vent.

Inflow prevention

Cross contamination and security have brought about many new approaches to protecting our drinking water. One of these is the concept of inflow prevention.

Inflow prevention is defined as preventing contaminated water from entering a potable water pipeline or reservoir through an air valve or reservoir vent. It is very similar to backflow prevention in that it impedes contaminated water from compromising drinking water; however, most backflow prevention is conceived of as an inline device that reacts to pipeline pressure changes. The inflow prevention concept is conceived of as a way to stop contaminated water from reaching an air valve or vent outlet while allowing the valve or vent to perform its function. An inflow preventer is a device that prevents the admittance of contaminated water or other fluids into a potable water pipeline or reservoir. Inflow preventers are installed on the outlets of air valves and reservoir vents.

In addition to keeping contaminated water away from drinking water, backflow and inflow preventers share two other concepts: the need for inspection and testing in the field to ensure that the device is functioning properly, and the need for redundancy. The concept of inflow prevention provides for these capabilities. Standards currently under development will most likely include provisions for both annual inspection and field-testing.

By following the successful and proven path of the backflow community and including field inspection, field testing and operational redundancy inflow prevention is proving to be as essential as backflow prevention.

Reducing vulnerability

Inflow prevention is important because air valves and reservoir vents are vulnerable to cross connection as well as malicious tampering. There are two types of air valve vault installations, unpiped and piped above grade with a J pipe. Left unpiped, an air valve outlet is exposed to the atmosphere. If the vault floods and the air valve opens, contaminated floodwater will be drawn into the system. If piped above grade, the same will happen if the floodwater reaches the elevation of the top of the J pipe.

Worse can happen through malicious tampering. It is a simple matter to cut off the top of a J pipe or drill a hole into it with a portable drill. Once done, a corrosive liquid can be poured down the J pipe, destroying the valve and leading to flooding and contamination. Worse, a bio-toxin such as ricin or botulinum could be poured down the pipe with very serious public health consequences. Inflow preventers can substantially reduce these threats.

Download: Here

Sponsored Recommendations

Blower Package Integration

March 20, 2024
See how an integrated blower package can save you time, money, and energy, in a wastewater treatment system. With package integration, you have a completely integrated blower ...

Strut Comparison Chart

March 12, 2024
Conduit support systems are an integral part of construction infrastructure. Compare steel, aluminum and fiberglass strut support systems.

Energy Efficient System Design for WWTPs

Feb. 7, 2024
System splitting with adaptive control reduces electrical, maintenance, and initial investment costs.

Blower Isentropic Efficiency Explained

Feb. 7, 2024
Learn more about isentropic efficiency and specific performance as they relate to blowers.