Valves: Controlling Flooding in Colombia

April 28, 2016
Hydroelectric plant solves flooding with automatic control valve

About the author: Patricio Egan is manager for Latin America - Spain and Portugal for Singer Valve. Egan can be reached at [email protected].

The Colombian state of Antioquia creates much of its clean power from hydroelectric plants along the Guadalupe River. In the case of the Guadalupe IV hydroelectric plant, the risk of flooding required that a suitable solution be provided to ensure the ejector pumps would work regardless of power or pressure differentials.

The plant generates power with three vertical axis turbines that discharge water below the river level. The lower part of the plant is susceptible to water leakage and is designed to continue operating with a certain amount of flooding. The river runs beside the roundhouse that discharges water from the three turbine units.

The leakage of the filtered water from the turbines, hydraulic valves, regulators, water snails, penstocks and draft tube cones is collected in a well. Three vertical pumps are installed inside the draw-well; two pumps have a suction capacity of 1,585 gal per minute (gpm), and there is a flooding pump with capacity of 3,170 gpm. The pumped water travels through two 30-in. pipes that discharge into the river. 

Level sensors are installed on the drainpipe so when the level in the sump reaches 330 cm above the bottom slab, a signal is generated to indicate potential flood risk. This in turn signals a butterfly valve installed on the valve chamber to partially shut down the plant. The plant is not able to generate the power it should until the problem is rectified.

After several flooding events, the Guadalupe IV hydroelectric plant designed a group of ejectors that do not depend on the electrical systems and serve as a reliable backup should flooding occur. With this system in place, the power plant can continue to produce uninterrupted power to its customers.

The ejectors receive water through a 6-in. pipe with three legs installed upstream of the generator’s inlet valves. The inlet pressure generated is 580 psi static pressure with a total flow of approximately 3,724.75 gpm. The problem is the ejectors are designed for specific flow and pressure conditions, so any changes on those variable values affect performance significantly. The optimum operating conditions for those ejectors are 1,268 gpm at 392 psi.

Ensuring Consistency

To ensure these variable conditions remain constant, the engineering team looked at installing automatic control valves.

The original project was designed with a plunger valve; however, the pressure drop across the valve would cause cavitation, which can be loud, cause vibration, choke the flow and create erosion that results in equipment failure and surging—which can in turn lead to pipe bursts. 

After further evaluation, the team chose Singer Valve’s 8-in. pressure-reducing control valve with anti-cavitation trim.   

This valve comes with single rolling diaphragm (SRD) technology that provides smooth, steady and precise pressure control from maximum to virtually zero flow. The effective area of an SRD remains constant so the bonnet is much smaller and lighter than a flat diaphragm version. A measured quantity into the bonnet control chamber always gives the same smooth movement of the inner valve through the entire stroke. A smaller bonnet also makes the valve lighter and safer to maintain, while the smaller control chamber enables it to respond faster to changing pressure. By eliminating the seat chatter at low flows, the SRD avoids injecting small pressure pulses into the piping, which, over time, may increase leakage, losses or pipe bursts.

The anti-cavitation cages are designed for a flow of 1,268 gpm and can reduce the pressure up to 392 psi, thus allowing the ejectors to operate at optimum conditions. This anti-cavitation technology contains two heavy stainless steel sliding cages that maximize the full flow capacity. The first cage directs and contains the cavitation recovery, allowing it to dissipate harmlessly. The second cage allows further control to a level as low as atmospheric pressure downstream.

“By installing this pressure-reducing control valve with anti-cavitation instead of the original plunger valve, we reduced the cost of the operation from 130 million Colombian pesos [$70,000] to 18 million Colombian pesos [$9,800],” said Engineer Santiago Ramirez, spokesperson for the hydroelectric plant.

Download: Here

About the Author

Patricio Egan

Sponsored Recommendations

Blower Package Integration

March 20, 2024
See how an integrated blower package can save you time, money, and energy, in a wastewater treatment system. With package integration, you have a completely integrated blower ...

Strut Comparison Chart

March 12, 2024
Conduit support systems are an integral part of construction infrastructure. Compare steel, aluminum and fiberglass strut support systems.

Energy Efficient System Design for WWTPs

Feb. 7, 2024
System splitting with adaptive control reduces electrical, maintenance, and initial investment costs.

Blower Isentropic Efficiency Explained

Feb. 7, 2024
Learn more about isentropic efficiency and specific performance as they relate to blowers.
singer-logo-smaller-102317_1
singer-logo-smaller-102317_1
singer-logo-smaller-102317_1
singer-logo-smaller-102317_1
singer-logo-smaller-102317_1
Directory

Singer Valve

March 22, 2022