Montreal Replaces Disinfection Systems at City’s Two Largest Plants

June 17, 2009
City is replacing chlorine gas disinfection systems with eleven OSEC B-Pak sodium hypochlorite generation systems from Siemens

The city of Montreal is replacing its chlorine gas disinfection systems with eleven OSEC B-Pak sodium hypochlorite generation systems from Siemens Water Technologies at two of the city’s largest water treatment plants (WTPs)–-Atwater and Charles J. Des Baillets. A local consortium comprised of Filtrum, Inc. and Siemens will provide the design, supply, installation, commissioning and training of the multi-million-dollar OSEC systems, which mark the largest such installations in Canada. These systems will help the city comply with new stringent government regulations for drinking water quality.

Combined, the plants treat roughly 634 million gal per day and serve approximately 1.6 million residents. These plant optimizations are part of a multi-billion-dollar project that includes the update of all WTPs as well as the distribution system on the Island of Montreal.

Five OSEC B-Pak systems will be installed at the Des Baillets WTP for a capacity of 7,500 ppd; six others will be installed at the Atwater plant for a capacity of 9,000 ppd. The systems at the Des Baillets plant are expected to be operational next year; those at the Atwater plant, in 2012.

By producing hypochlorite on site and on demand, the OSEC system eliminates concerns associated with transportation and storage of liquefied chlorine gas or commercial sodium hypochlorite solutions, making it ideal for any application requiring chlorination. And contrary to high-strength commercial sodium hypochlorite solutions, the low concentration of the hypochlorite solution generated by the OSEC B-Pak system minimizes corrosion and degradation. In addition, extensive safety measures are taken in disposing of hydrogen, the system’s only byproduct. Neither special safety equipment nor clothing associated with usage of chlorine gas is needed, nor does a costly risk management plan need to be implemented and maintained. The small-footprint OSEC B-Pak skid system is a fully automated, prepackaged on-site hypochlorite generation system designed for fast and economical installation, safe operation and easy maintenance. Skids are shipped completely piped, wired and tested. The OSEC system generates a 0.8% sodium hypochlorite solution through the electrolysis of brine, consuming only water, salt and electricity. The system also ensures accurate and reliable brine measurement for high efficiencies.

The city of Montreal worked with consultant Consortium SNC-Lavlin/Dessau-Soprin (Montreal), contractor Filtrum, Inc. (Quebec City), and equipment manufacturer Siemens Water Technologies on the project.

During the past six decades, the city of Montreal and Siemens have worked together on a number of projects. For example, Wallace & Tiernan gas chlorination and analytical equipment are installed at both the Atwater and Charles J. Des Baillets plants. Similar equipment, as well as Wallace & Tiernan metering pumps and dry feeders, is also installed at other Montreal plants.

Source: Siemens

Sponsored Recommendations

Benefits of Working with Prefabricated Electrical Conduit

Aug. 14, 2024
Learn how prefabrication of electrical conduit can mitigate risk, increase safety and consistency, and save money.

Electrical Conduit Cost Savings: A Must-Have Guide for Engineers & Contractors

Aug. 14, 2024
To help identify cost savings that don’t cut corners on quality, Champion Fiberglass developed a free resource for engineers and contractors.

Get Utility Project Solutions

June 13, 2024
Lightweight, durable fiberglass conduit provides engineering benefits, performance and drives savings for successful utility project outcomes.

Energy Efficient System Design for WWTPs

May 24, 2024
System splitting with adaptive control reduces electrical, maintenance, and initial investment costs.