Xylem Provides High-Tech Bypass During Kiski Valley Treatment Plant Upgrade

Oct. 9, 2019

To stay in compliance with state Environmental Protection Agency requirements, the Kiski Valley Water Pollution Control Authority (KVWPCA) in Pennsylvania had to double the capacity of one of its plants – from 15 million gallons per day (MGD) to 31 MGD.

As part of the expansion process, KVWPCA needed to decommission their existing influent pumping station and tie into a new influent pump station once construction was completed. To enable all that to happen, KVWPCA – with help from an engineering contractor and Xylem – built a bypass pumping system that could handle the flow as the construction process was taking place.

Xylem recommended and installed five Flygt NS-3301 electric submersible pumps for a temporary rental installation. Since the plant didn’t have enough power to run the pumps, each pump ran off of a 104-kilowatt Godwin generator. Each generator was equipped with a 100-horsepower Godwin VFD to handle the variations in flow. Two 24-inch Xylem brand MJK flow meters were also installed, in addition to level transducers in the wet well.

At the core of the project was a remote supervisory control and data acquisition (SCADA) system that Xylem installed to drive the monitoring and control aspect. The SCADA system received data from level transducers in the wet well, which triggered the generators and started the pumps at pre-determined levels. The VFDs then controlled pump speed to maintain appropriate system flow.

The pumps, generators and VFDs were all installed to work sequentially. For optimal efficiency and to save energy and diesel fuel costs, each pump activated only when increased flows called for additional pump activity. During low-flow activity, one or possibly two pumps were needed. At peak-flow activity, three or four pumps kicked on. The fifth pump was programmed to start running only as a back-up if any of the other four pumps failed.

Linked together to work in tandem via SCADA, the VFDs fed real-time run data – including RPM speed, AMPS current and levels measured in feet – from the pumps to the display. The system parameters were pre-set at specified levels, and sent KVWPCA personnel text alerts to their mobile phones in the case that any parameter was not being met, or if the equipment wasn’t running at optimal levels.

The remote SCADA tied back to the plant SCADA, so plant personnel could monitor all activity from one single control panel. Providing real-time visibility of the entire process, the remote SCADA was also accessible from any device with Internet access, including smart phones, for ultimate monitoring and control.

Over the life of the long-term project, the Xylem technology used by Kiski Valley – most notably the SCADA system and the precise on/off control of the onsite equipment – saved thousands of dollars through increased energy efficiencies. The real-time, advanced remote monitoring and control technology supplied and installed by Xylem also provided KVWPCA personnel and their customers with peace-of-mind.

Editor's Note: Scranton Gillette Communications and the SGC Water Group are not liable for the accuracy, efficacy and validity of the claims made in this piece. The views expressed in this content do not reflect the position of the editorial teams of Water & Wastes Digest, Water Quality Products and Storm Water Solutions.

Sponsored Recommendations

Blower Package Integration

March 20, 2024
See how an integrated blower package can save you time, money, and energy, in a wastewater treatment system. With package integration, you have a completely integrated blower ...

Strut Comparison Chart

March 12, 2024
Conduit support systems are an integral part of construction infrastructure. Compare steel, aluminum and fiberglass strut support systems.

Energy Efficient System Design for WWTPs

Feb. 7, 2024
System splitting with adaptive control reduces electrical, maintenance, and initial investment costs.

Blower Isentropic Efficiency Explained

Feb. 7, 2024
Learn more about isentropic efficiency and specific performance as they relate to blowers.