Packaged System Reduces Arsenic Levels in Chilean Community

Jan. 27, 2016
The treatment system reduced arsenic concentrations to non-detectable levels
undefined

The residential subdivision of Alto Lampa is a rapidly developing neighborhood located just outside of Santiago de Chile. The community is served by two wells, each with a flow of 800 gal per minute, running one at a time. Both wells produce raw water with high arsenic concentrations that fluctuate between 0.015 mg/L and 0.030 mg/L, which is above the World Health Organization’s level of 0.010 mg/L.

The system is managed by Aguas Andinas, which is the largest municipal water provider in Chile. In 2012, the project was awarded to EcoRiles who then contracted AdEdge Water Technologies to supply and start up the treatment system.

Treatment System

The AdEdge arsenic treatment approach consists of two WaterPOD containerized treatment systems, each with five 48-in. diameter carbon steel vessels arranged in a parallel configuration. The vessels are loaded with AdEdge’s Bayoxide E33 granular ferric oxide adsorption media. The E33 allows the arsenic to remain bound to the media structure and does not become loose during backwash. The system has chemical dosing and backwash recycle equipment built inside the WaterPODs.

A section of the first WaterPOD was partitioned to serve as a chemical room separated from the rest of the equipment to avoid corrosion from chemical off-gassing. Inside the chemical room, there are separate partitions for the two chemicals (sodium hypochlorite and hydrochloric acid) to further segregate the chemicals and avoid unintentional mixing. Sodium hypochlorite is added to oxidize the arsenic from trivalent to pentavalent and hydrochloric acid is added to lower the pH and improve media life.

The second WaterPOD contains the equipment for the backwash recycle pump and bag filters. The backwash holding tank was situated outside of the WaterPODs. The system performs backwash of the vessels every 45 to 60 days to prevent hydraulic channeling and to remove any suspended solids that may have accumulated in the bed. Backwash operations are automatically controlled by an AdEdge InGenius control panel with PLC and HMI. The source of the water is treated water from the outlet of the distribution pumps.

Performance

The system was successfully started up in early August 2013. Recent testing of the water shows the treated water having non-detectable concentrations of arsenic.

Richard J. Cavagnaro is marketing coordinator for AdEdge Water Technologies LLC. Cavagnaro can be reached at [email protected] or 678.835.0052.

Sponsored Recommendations

Blower Package Integration

March 20, 2024
See how an integrated blower package can save you time, money, and energy, in a wastewater treatment system. With package integration, you have a completely integrated blower ...

Strut Comparison Chart

March 12, 2024
Conduit support systems are an integral part of construction infrastructure. Compare steel, aluminum and fiberglass strut support systems.

Energy Efficient System Design for WWTPs

Feb. 7, 2024
System splitting with adaptive control reduces electrical, maintenance, and initial investment costs.

Blower Isentropic Efficiency Explained

Feb. 7, 2024
Learn more about isentropic efficiency and specific performance as they relate to blowers.