Neptune Chemical Pump Co. Offers Tips on Selecting Metering Pumps

Feb. 19, 2010
Company creates technical bulletin

Neptune Chemical Pump Co. has a full line of metering pumps. To assist its customers and clients, Neptune has created a technical bulletin titled, “Sizing and Selecting Metering Pumps—Planning a Metering Pump Installation.” The technical bulletin, which is available free via the Internet at http://www.neptune1.com/pumps/sizing-select-guide.htm is meant to be a guide to help the user define the variables that need to be evaluated for proper selection and installation of a chemical metering pump or a complete chemical feed system.

The first step in effective metering pump sizing is determining the size needed in terms of both the pump’s flow rate and discharge pressure. Metering pumps should not be over-sized but rather the maximum expected flow should be 85% to 90% of the pump’s capacity; the minimum capacity should never be less than 10% of capacity.

The best type of metering pump for an application cannot be determined until the proper flow rates, discharge pressures and types of fluids to be handled at identified, Neptune said. Drive end choices are hydraulic diaphragm, mechanically actuated diaphragm or solenoid. Choice of liquid end designs are available for corrosive, viscous or slurry applications.

Liquid end options include double diaphragm heads with leak detection and alarm capabilities for applications where diaphragm failures must be sensed immediately. Drivers must be matched to the available utilities, including electric, air, gas or other means of driving the pump. Knowing the atmosphere in which the pump will operate also plays a role when selecting the driver, as hazardous area requirements must be identified.

Method of control is also a crucial choice, with manual continuous operation, on/off operation and automatic proportional control in response to a process signal the usual choices. Micrometer dials can be manually adjusted to control flow rates, allowing the pump to be operated between 10% and 100% of capacity depending on the stroke length. Flow rates can also be controlled automatically by electric positioners that change the pump’s stroke length in response to a process signal, or by variable speed drives that alter stroking speed.

Source: Neptune Chemical Pump Co.

Sponsored Recommendations

Blower Package Integration

March 20, 2024
See how an integrated blower package can save you time, money, and energy, in a wastewater treatment system. With package integration, you have a completely integrated blower ...

Strut Comparison Chart

March 12, 2024
Conduit support systems are an integral part of construction infrastructure. Compare steel, aluminum and fiberglass strut support systems.

Energy Efficient System Design for WWTPs

Feb. 7, 2024
System splitting with adaptive control reduces electrical, maintenance, and initial investment costs.

Blower Isentropic Efficiency Explained

Feb. 7, 2024
Learn more about isentropic efficiency and specific performance as they relate to blowers.