With various types of wastewater pumps available, this paper discusses criteria that may be used by sanitation agencies in selecting the type of wastewater pump for a particular project or application. Capital cost, operation and maintenance (O&M) costs, and other relevant criteria are evaluated. The evaluation included investigating wastewater pumping station design and O&M procedures at 15 cities or sanitation agencies in the United States having more than 2,700 pumping stations among them. More than 50 pumping stations were visited and observed.
Several types of wastewater pumps are available:
In determining the type of pump to use, life-cycle economic costs are a major (although not the only) factor for the analysis. Data will be presented in the following sections on estimates for initial construction costs for pumping stations using these three types of pumps and estimates of O&M costs. The data on O&M costs was determined from interviews with users of operating facilities.
Description of Pump Types
Reference [1] provides a detailed discussion and description of these pumps. The following are brief summary descriptions.
On the other hand, submersible pumps are not readily accessible for inspection and service, give little warning of incipient problems, and may require shipment to qualified service centers for motor or seal repairs. This tends to lead to higher service and maintenance cost and longer turnaround times. Statements about low maintenance costs can be misleading when based on short-term (e.g., two years or less) experience.
In wet well installations, submersible pumps can be installed with fixed discharge piping and can be supported by a tripod or a similar device mounted on the wet well floor. This type requires draining of the wet well for any kind of inspection, service or maintenance. A more popular method for installing submersible pumps is the pull-up design in which the discharge piping is connected to a special elbow that is permanently mounted on the wet well floor. The elbow and the pump discharge nozzle are equipped with a self-locking coupling. Because the pump mounting bracket slides up and down on two rails, it can be raised from the wet well or lowered onto the elbow by a crane and a cable with no need for personnel to enter the wet well or to drain it.
Some pumps with submersible motors must be immersed for continuous operation for external-cooling purposes and can run only for intermittent periods of time if exposed to air. Other submersible pumps have motors with internal cooling systems and can run continuously at full load without immersion. Pumps with internally cooled motors also are available for dry well installation where they have the advantage of being resistant to damage if the dry well is accidentally flooded. However, this pump comes at higher capital cost (Figure 6).
The pump is installed on top of the wet well and requires no dry well. The driver, either a motor or an angle gear, is mounted on top of the pump discharge head. Standard drivers with any desired design or control options are used. The driver is readily accessible for service or maintenance. The symmetrical bowl design eliminates radial thrust forces, and discharge connections can be arranged above or below ground. Although the pump itself is expensive, the total cost of a pumping station may be reduced because the concept eliminates the need for a dry well.
U.S. Sanitation Agencies
A great amount of data on O&M costs and practical experience with the three types of pumping stations was determined as part of a study [2] that included conducting telephone interviews or personal interviews with operations and maintenance supervisors and chief engineers at 15 public sanitation agencies. In addition, six more agencies having vertical, turbine-type solids handling pumps were contacted to discuss their experience with this particular type of pump. The 15 agencies had more than 2,700 raw sewage pumping stations among them. Based on the interviews, four large agencies (having more than 1,000 pumping stations) were then visited. Interviews were conducted with O&M personnel and engineers to determine engineering and O&M practices, what problems they frequently encounter, and to understand preferences they have with regard to improving design and O&M characteristics of the pumping stations. Finally, more than 50 pumping stations were visited. Operations were observed and the actual pumping station O&M personnel were interviewed.
The main conclusions derived from these interviews and site visits were as follows.
·Raw sewage pumping stations are heavy-duty service types of facilities. They are definitely not light or medium duty facilities. This is especially true of submerged equipment in raw sewage pumping stations. Raw sewage pumping stations require a degree of ruggedness and reliability in equipment that can be met only by manufacturers and suppliers who understand these requirements.
Construction, O&M and Life Cycle Cost Estimates
Opinions of probable construction costs were developed for the various alternative pumping station designs. These opinions of probable construction did not include costs for site specific items such as massive earthwork, unusually extensive landscaping and extensive access roads. An allowance was included to account for a "normal" amount of site grading, landscaping, fencing, paving and drainage. The data for construction costs are taken from References [1], [2] and [3]. These construction cost estimates represent costs likely to be encountered in urbanized areas and are thought to be conservative in that they probably represent above-average costs.
It was not possible to establish absolute O&M costs for most of the alternatives. None of the sanitation agencies contacted or visited had precise data on O&M costs per pumping station or for various types of pumping stations. However, all these agencies did have some idea of the differential costs in terms of repair costs and maintenance labor efforts between conventional dry well/wet well pumping stations and submersible pumping stations. These differential O&M costs were used in developing comparable life cycle costs that could be used in the analysis.
Mechanical Screening Systems
In theory, mechanical screens are installed to
In reviewing the practices at various sanitation agencies in the United States, we were not able to find that screens are really necessary at most wastewater pumping stations. The fifteen sanitation agencies contacted had approximately 2,700 raw sewage pumping stations between them. Only 10 to 15 percent of these stations had mechanical screening or grinding systems of any kind. Only one agency required mechanical screens or grinders at all pumping stations. This agency reported that they consistently get large quantities of construction debris (pieces of brick and masonry, lumber, drill bits, bolts, nails, etc.) in their sewage and they need to have screens or grinders ahead of the pumps in order to avoid excessively high wear and tear on the pumps with the associated high maintenance costs. This does not appear to be a typical or common occurrence in municipal sewage systems in the United States, although it may be a more common problem in Latin America and Asia.
The general consensus of most maintenance supervisors at these agencies in the United States is that
It is felt that the above observations are relevant to wastewater pumping stations constructed in North American and Europe, where source control methods and regulations are reasonably well developed. Wastewater pumping stations constructed in Asia and Latin American most likely should incorporate screening systems. Incorporating mechanical screening systems into conventional wet well/dry well pumping stations typically increases construction costs by about 25 percent as shown in Table 1.
O&M Aspects of Deleting Screens: O&M costs could be increased or decreased with this alternative because of the following reasons:
References
About the Authors:
Bayard Bosserman, P.E., is principal engineer with Boyle Engineering Corp., Newport Beach, CA.
Paul Behnke, P.E., is manager of engineering and quality, Ingersoll-Dresser Pump Co., Taneytown, MD.