News
Articles
Case Histories
Webinars
White Papers
Tank Calculators
Buyer's Guide
Career Center
February 2010
January 2010
March Card Deck 2010
WEFTEC.09: Part 1
WEFTEC.09: Part 2
Arsenic
Decentralized Wastewater
Filtration
Flow Measurement
Headworks
Membrane Technology
Pumps
Ultraviolet Disinfection
Click here for a subscription to
Water & Wastes Digest
Give us your feedback on our site.
Change your subscription info
Subscribe to our
WQP/WWD Executive NewsSummary e-Newsletter.
EDITORIAL CATEGORY - TANKS
Chemical Tank Cleaning Eliminates Town's Chlorine Demand   Water & Wastes Digest May 2003   Ulrich Reimann-Philipp, Ph.D.
Finished water quality often declines in storage facilities. Traditional tank cleaning methods have some effect in removing loose debris and sediment, but leave most of the scale, metal oxide deposits and biological growth in place. Chemical cleaning methods have been widely applied in Europe for years and have become an essential part of preserving water quality in systems which operate with minimal or no chlorine.
Aeration for Ponds and Cisterns   Water Quality Products January 2003   Jeff Roseman, Aqua Ion Plus+ Technologies
Using oxygen for the natural cleansing of water is becoming a viable alternative for pond and cistern owners in reducing the use of chemicals to fight the bacteria and algae that can become a nuisance. An aerobic bacterium needs oxygen in order to maintain the balance of nature. This article will take a look at some methods for increasing oxygen content, Henry's Law and applications that benefit from increased levels of O2.
PDF Version
Portable Tanks Help In Gas Pipeline Expansion Project   Water & Wastes Digest May 2002
By reclassifying the existing pipeline, PG&E avoided the enormous expense of laying 38 miles of new pipe. The primary objectives of the project were to safely raise natural gas pipeline pressure without increasing the release of nitrogen oxide (NOx) into the atmosphere. These objectives were achieved by relocating two pressure limiting stations, retrofitting two internal combustion compressors, and performing pipeline hydrotesting operations.
Tanks Pull Double Duty   Water Engineering & Management February 2002   Dan Zienty
Following the adoption of the Telecommunications Act of 1996, water storage facilities have become fair game for the installation of antennas and associated ground equipment. A storage tank pulling double duty raises maintenance and safety issues for consideration by municipalities and their system operators.
PDF Version
Minimizing Out-of-Service Time During Tank Painting   Water Engineering & Management February 2002
Tank painting projects can cost many thousands of dollars, but often the most costly aspect of tank rehabilitation is having your tank out of service. What can be done to get your tank back in service sooner? One approach is to control the environment and minimize delays due to poor weather. Another is to use coatings that tolerate a wide range of climatic conditions and cure quickly at ambient temperature. By combining these methods, down-time can be greatly reduced.
PDF Version
Long-Term Settlement of a Large Water Standpipe   Water Engineering & Management May 2001   Steven Law and John Kasprzak
When tank settlement is anticipated, certain precautions must be taken to assure that the tank settles properly.
PDF Version
Wastewater Impoundment Converted To Process Tank At Georgia Chemical Company   Water & Wastes Digest May 2001
Fisher Tank Company of Chester, Pa., has placed a leakproof steel liner into a 260-ft.-diameter, 14-ft.-deep wastewater treatment facility at the caprolactam production plant of DSM Chemicals North America, Inc., near Augusta, Georgia.
PDF Version
Storage Tanks Insulated with Urethane Foam Increase Energy Efficiency   Water & Wastes Digest May 2001
A spray-applied coating and insulation system to protect anhydrous ammonia fertilizer tanks from temperature variations has been useful at beverage, fertilizer and chemical facilities worldwide.
PDF Version
Environmental Control Speeds Water Tank Project   Water Engineering & Management April 2001
Concerns about expenses, deadlines and the environment all came into play when the Helix Water District near San Diego, Calif., had to recoat a four-million-gallon water storage tank.
Bulk Tank Polymer Hauler Uses Economical Separator - Wins State, Local Ecological Awards   Water & Wastes Digest March 2001   WWD Staff
Trimac Transportation Company of Hayward, Calif. has been awarded a Certificate of Merit from the California Water Environment Association and the Hayward Environmental Achievement Award for Industrial Wastewater Control.
PDF Version
Hollywood Stays Green Using Underground Water Tanks   Water Engineering & Management February 2001
When you literally cannot move mountains, you must figure out a way to work around them.
Waterborne Coatings for Water and Wastewater Treatment Plants: Part 2   Water Engineering & Management February 2001   Tony Ippoliti
Waterborne acrylic coatings are available in single-component formulations that offer good durability, exceptional resistance to UV light and long-term flexibility.
Ohio Wastewater Treatment Plant Installs Covers On Sludge Digester Tanks   Water & Wastes Digest January 2001
Attempting to maintain aerobic conditions in two large, municipal thickened sludge digesters created problems in an Ohio community. High aeration rates caused splashing out of the digesters, while lowering the aeration rates to reduce the splashing created additional odors.
PDF Version
Water Storage Tank Fulfills Water Needs   Water Engineering & Management August 2000
A conspicuous structure with alternating red and white stripes stands in the City of Sylacauga, 45 miles southeast of Birmingham, Ala. The brightly colored, towering object is a new water storage tank, the largest to be built in the city and a crucial contribution to the city’s present water needs and future growth.
San Diego Tank Structure Wins Award   Water & Wastes Digest May 2000
Demand for additional sewerage system capacity and the need to reclaim wastewater in San Diego’s arid region led the City of San Diego Metropolitan Wastewater Department, San Diego, California, to construct two 3.5 MG flow equalization basins at the North City Water Reclamation Plant (NCWRP).
Temporary Wastewater Tank Installation Leaves No Footprint When Removed   Water & Wastes Digest May 2000
Remediation of contaminated sites and return of contaminated land to a natural or reusable state has become an important requirement for business and government alike.
FRP Linings in Above-Ground Storage Tanks: How Strong Are They?   Water Engineering & Management May 2000   Bob Hummel
Chemicals can be severely corrosive to above-ground metal storage tanks, resulting in possible leaks.
PDF Version
Disappearing Colorant Ensures Uniform Coverage Of Protective Coatings   Water & Wastes Digest January 2000
A patented fugitive colorant helps facilitate uniform application of clear protective finishes applied to water storage tanks and vessels and boasts many other advantages.
Protecting Concrete Tanks in Water and Wastewater Treatment Plants   Water Engineering & Management September 1998   Greg Illig, P.E.
Special methods and materials must be used to protect concrete tanks from the harsh environment in water and wastewater facilities.
PDF Version
Protecting Water Storage Tanks in an Era of Environmental Compliance   Water Engineering & Management November 1996   Dallas Finch
Learning more about the causes of corrosion in an on water storage tanks can lead to the right coating choice for the tank site.
PDF Version
Maintenance History of Four Steel Water Tanks   Water Engineering & Management July 1995   Walter Neumann, Jr. and Wade D. Newman
A survey looked the maintenance painting costs for four large-capacity steel water tanks
Home   |   Advertising   |   News Search   |   Articles   |   Buyer's Guide   |   Career Center   |   Case Histories   |   Top of Page